Translate

Showing posts with label electric. Show all posts
Showing posts with label electric. Show all posts

April 08, 2014

Modular #connection #box

Special modular production technique allows clients to order customized #spider distribution box.
The connection box is totally overmolded with thermoplastic polyurethane.
Tools flexibility makes these products application convenient even for small production lots on a wide range of #machinery and #equipment.
Customized configuration can be delivered in quantity of 1 or 20 or 100 or even thousands pieces with very good cost/quality ratio.
Machine manufacturer gets finished items ready for plug and play assembly.
Many standard configurations are available as well.
Distribution Spider with custom configuration
Spider harnesses connection with plugs, sockets and cables.
Advantages:
1. Optional devices can be connected, if necessary.
2. Easy and quick “plug & play” assembly.
3. Reduction in time wiring and easy maintenance.
4. Significant reduction of weight and overall dimensions.
5. Reduction in number of machinery spare parts.
6. Avoid cable waste during machine assembly.
7. Long life and robustness. Very good cost/quality ratio.

Link to www.shield.net for Company website.
Link here for more photos about Shield’s production .


March 17, 2014

#Safety #circuits

Distribution box with M12 connector 5-pin or 8-pin
IP67 electrical signal distributor for Safety Applications
Distributor device and #M12 #connectors with 5 or 8 poles
for application with safety circuits.
  • Standard circuits available to connect safety sensors.
  • Overvoltage category III, pollution degree 3.
  • Yellow body.
  • Customized circuit availability.
Click for larger photo
Click for all photos of Shield’s product on Flickr


June 25, 2010

#Current-carrying #Capacity. Ambient Air and Cable Temperature

How to choose the #cable #section.
The current flow in a connector and in its cable generates heat, thus a temperature rise. Any connector or cable insulating material has a maximum safety temperature that should never be exceeded to ensure the stability of their mechanical properties.
After verifying the insulating material quality and the working ambient air temperature, the maximum current-carrying capacity permitted in the connector can be calculated in function of the terminals size and the conductors section.
Current Carrying CapacityTable 2 on page http://www.shield.net/files/catalogue/support/2.2.pdf shows the maximum current values for a pvc cable (quality 70°C) with 2 or 3 wires without metal sheath, with copper conductors, employed for normal use and inserted into cable tray. For open air applications a current about 10% higher is admitted.
The ambient air temperature is measured around the cable, for example inside the cabinet or close to the machine interspaces. The right ambient air temperature is found after the normal functioning of the machine, under full load for a sufficient period of time, without taking into account the variations of the temperature due to heating of the cable. If the use does not require a higher temperature project, the conventional value of 40°C (IEC 60204-1) must be considered.
The table takes into account that in most of the machines not all cables are used simultaneously for long periods. In special cases (many wires used at the same time or high ambient air temperatures), a reduction factor of between 0,3 and 0,9 must be used to reflect the overheating of cables in the same group, otherwise verify that the temperature remains within the limits allowed. Particular attention must also be paid to vertical and limited ventilation routes.
Values and comments refer to IEC 60204-1 (Machinery Safety, edition October 2005) and IEC 60364-5-52 (Wiring Systems Security).