6-signal #splitter of small dimensions


Splitter for several #actuators / #sensors, M8, M12 connectors, plugs or sockets.
Application: When there are many sensors and solenoid valves in small space.
For example the head of industrial #robot.
Each 8-pole M12 connector can drive from 1 up to 6 connectors M8.
Advantages:
  • Reduces weight
  • Reduces dimensions
  • Very quick assembling
  • Reduces inventory codes
  • Easier maintenance
  • Possible customizations
  • Spiral cables are available as well
    Splitter and cable
    Up to 6-signal splitter, spiral or straight cable

January 25, 2013

Distribution box for #electrical #cabinet panel

Distributor with M8 or M12 connectors
It can be mounted on the front of an electrical panel or cabinet.

Distribox can have a rear cable or a simple rear terminal block.
In this way, the #distribution #box can be mounted on the front of an electrical panel or cabinet.
Available with M12, M8 connectors, female sockets or male plugs.


November 16, 2012

Y Splitter, #M12-M12 #connector

Splitter useful to join on the same cable the signals coming from 2 different #sensors or to control 2 #electrovalves.
Solutions with direct cable instead of plug or socket connectors are available as well.
 
distributor M8-M8, M-M12-M12, M8-M12
Splitter allows to use 1 single cable for 2 sensors or 2 valves.
Variants: each connector could be replaced by a cable,
moreover each connector could be male or female type.



June 25, 2010

#Current-carrying #Capacity. Cable Voltage Drop

Cable choice.
An important element of assessment is the length of the cable. Each meter of the cable causes a voltage drop proportional to the value of the current that runs through it, if cosf = 1 we have: V = IxR.
Max Cable CurrentV = voltage drop, I = current, R = resistance of the cable. In the case of inductive loads (solenoid valves, motors, etc.) or with variable currents, the higher current peak must be considered to avoid even temporary loss of power, which could hinder the proper functioning of the equipment. The longer is the cable, the greater the #voltage #drop, the IEC allows maximum values drop from 3% to 5% of rated voltage. Greater values are admitted only for the current peaks (e.g.: engines starting), if they do not create functioning problems. To minimize the voltage drop the cable section should be increased. Here are some tables that can help to easily calculate the minimum theoretical cable section. See tables 3 and 4 on the page http://www.shield.net/files/catalogue/support/2.2.pdf.
For example, an average continuous current 1 A with section 0,34 mm2 and cable length 10 m generates a voltage drop of 1,3 V, which is approximately 5% of 24 V.

#Cable Maximum Voltage Rating and #Mechanical Strength

Tips to choose a cable.
The maximum voltage depends on the material characteristics, the conductor insulation thickness and the outer sheath thickness. The insulation must be sufficiently resistant to prevent even accidental crushing situations, so different uses can have different requirements of project. Norms as UL and CSA (American), IEC (International) and EN (European) set values which are not always equal to each other and sometimes refer only to heavy employment, such as cables for power transmission.
Cable max current
For the transmission of signals inside industrial machinery, it is frequent to use reduced thickness which refers to commercial standards which are not supported by norms, such as cables LiYY and FROR. The advantage of using reduced thickness is particularly evident in the smaller volume occupied by bundles of cables. The reference nominal voltage is generally at least 300 V. On the market there are also low-cost cables in PVC, with extremely reduced thickness, which may not be compatible with the safety standards for specific applications; it is advisable to carefully evaluate the characteristics of the products.
The norm IEC 60204-1 (#Machinery #Safety) recommends the minimum section of the cables according to the application as well, see table 1 on page http://www.shield.net/files/catalogue/support/2.2.pdf. The norm allows smaller sections only if the mechanical protection is sufficiently guaranteed, for example with conduits.

June 04, 2010

7/8" connectors

7/8" angled connector with cable. HDM Shield series connectors, angled shape, 7/8 inch thread. Poles quantity (from 2 to 14) and many combinations of thread and poles gender offer to the designer a wide range of different connections.#Shield manufactures #connectors for industrial #hydraulic, pneumatic, electrical #automation, illumination, trucks and various construction equipments. These photos show 7/8" circular angled and straight connector series with shielded or unshielded cable. The cable materials can be chosen among a wide choice: halogen free, polyurethane, PVC, silicone, etc. Dynamic or static application. 2, 3, 4, 5, 6, 14, 19, 25 poles.

7/8" straight connector with cable. HDL Shield series connectors, straight shape, 7/8 inch thread. With shielded or unshielded   cables. They are usually applied on small motors or distribution   boxes.7/8" frontal assembling receptacle with wires. HDE Shield series receptacles, 7/8 inch thread. Frontal assembling method. Poles quantity (from 2 to 14) and many combinations of thread and poles gender offer to the designer a wide range of connections.

Gender configurations can be: standard male, female and hybrid male-contacts / female-thread, female-contacts / male-thread. Ratings up to 13A, 600V. IP68 over-molded cables. Clean design.
Receptacle can be supplied with frontal or rear assembly method.

Manufacturer of M12 and M8 connectors

switches, connectors and cables for industrial automationpanel connectorsM12 connecteurs, Stecker, connectors, connettori
M8 and M12 with cable

Shield manufacturs #IEC 61076, IEC 60947-5-2 M8 and #M12 circular #connectors, angled or straight, with shielded or unshielded cables, halogen free polyurethane cables, PVC or silicone cables, dynamic or static application; circuits: Led or special circuit available. Ratings up to 4A, 250V. Clean design.