December 12, 2013

#D-Sub connector, small dimensions, with #IP67 IEC60529 protection

IP67 protection class D-Sub connection
Dsub connector with IP67 protection (EN IEC 60529)

Thanks to an innovative lip gasket, JxLF and JxMF series D-sub female connector family guarantees a high degree of #protection against #water and dust.
Can be mounted on any male connector plug already present on the market.
Terminals are crimped to wires, in this way ensure greater reliability compared to soldered or screwed terminals.
The housing may contain resistors or other electronic components, if requested.
PVC or PUR cable, with or without shielding. Standard wires with DIN 47100 colours.
Connection sockets from 9 to 62-pole, reliable and economic.
Angled or straight versions.

November 09, 2012

#Receptacles

M8, M12, M23, 7/8", female sockets or male plugs
Examples of receptacles for panel applications

#M8, #M12, #M23, 7/8", male plug or female socket, angled or straight for mounting on panel.
Available with unsheathed or sheathed wires, with soldering or for printed circuit contacts.


May 17, 2012

Distribution #Backbone #Chain


Chain made of electrical connections series.
The backbone is usually made with wires of 1,50 mm² or 2,5 mm².
Infinite number of connections.
The distance between 2 connections is upon request. Typically 1 meter.
Each output can be direct cable or connector, male or female, M8 or M12.
Example of application: #Led #illumination.

Electrical connections or wiring harnesses
Each output can be cable or connector.

June 25, 2010

#Cable Maximum Voltage Rating and #Mechanical Strength

Tips to choose a cable.
The maximum voltage depends on the material characteristics, the conductor insulation thickness and the outer sheath thickness. The insulation must be sufficiently resistant to prevent even accidental crushing situations, so different uses can have different requirements of project. Norms as UL and CSA (American), IEC (International) and EN (European) set values which are not always equal to each other and sometimes refer only to heavy employment, such as cables for power transmission.
Cable max current
For the transmission of signals inside industrial machinery, it is frequent to use reduced thickness which refers to commercial standards which are not supported by norms, such as cables LiYY and FROR. The advantage of using reduced thickness is particularly evident in the smaller volume occupied by bundles of cables. The reference nominal voltage is generally at least 300 V. On the market there are also low-cost cables in PVC, with extremely reduced thickness, which may not be compatible with the safety standards for specific applications; it is advisable to carefully evaluate the characteristics of the products.
The norm IEC 60204-1 (#Machinery #Safety) recommends the minimum section of the cables according to the application as well, see table 1 on page http://www.shield.net/files/catalogue/support/2.2.pdf. The norm allows smaller sections only if the mechanical protection is sufficiently guaranteed, for example with conduits.