April 08, 2014

Modular #connection #box

Special modular production technique allows clients to order customized #spider distribution box.
The connection box is totally overmolded with thermoplastic polyurethane.
Tools flexibility makes these products application convenient even for small production lots on a wide range of #machinery and #equipment.
Customized configuration can be delivered in quantity of 1 or 20 or 100 or even thousands pieces with very good cost/quality ratio.
Machine manufacturer gets finished items ready for plug and play assembly.
Many standard configurations are available as well.
Distribution Spider with custom configuration
Spider harnesses connection with plugs, sockets and cables.
Advantages:
1. Optional devices can be connected, if necessary.
2. Easy and quick “plug & play” assembly.
3. Reduction in time wiring and easy maintenance.
4. Significant reduction of weight and overall dimensions.
5. Reduction in number of machinery spare parts.
6. Avoid cable waste during machine assembly.
7. Long life and robustness. Very good cost/quality ratio.

Link to www.shield.net for Company website.
Link here for more photos about Shield’s production .


March 17, 2014

#Safety #circuits

Distribution box with M12 connector 5-pin or 8-pin
IP67 electrical signal distributor for Safety Applications
Distributor device and #M12 #connectors with 5 or 8 poles
for application with safety circuits.
  • Standard circuits available to connect safety sensors.
  • Overvoltage category III, pollution degree 3.
  • Yellow body.
  • Customized circuit availability.
Click for larger photo
Click for all photos of Shield’s product on Flickr


February 13, 2014

How to prevent #connectivity #mistakes

Shield manufactures distribution boxes with M12 connectors that can have different #mating #keys (IEC 61076-2-101 standard); in this way it is not possible to mount connectors in the wrong position. Moreover, to facilitate the assembly visually, connectors may have different colours as well in addition to the key.
Very useful for maintenance when box is positioned in difficult areas or when a connection mistake could cause delays or damages.
Connectors may have different colors and coding as well
Example of distribution box to prevent assembling mistakes.

September 25, 2013

#Coloured and/or A-B-C-D-P coded #M12 connectors

M12 - #IEC 61076-2-101 #connectors can be supplied with many different key codings to prevent assembly and maintenance mistakes.
Numbers of poles: from 2 up to 17.
Differently coloured connectors are also available to help easy matching, when plugs and sockets are positioned in difficult places for the operator.
M12 Connectors
Plugs and sockets to avoid error assembly.

March 11, 2013

#Electronic #Box for lighting information

electronic enclosure
This modular box can contain easily electronic components and lighting signals.

Distribox is a distribution box which can be also used to contain #lighting arrows or coloured #signals.
Distribox series is modular and dimensions can be according to customer’s project.
Advantages:
  • Small dimensions
  • Weightless
  • Good water proof
  • High efficiency
  • Low consumption
  • Design upon request as well

January 25, 2013

Distribution box for #electrical #cabinet panel

Distributor with M8 or M12 connectors
It can be mounted on the front of an electrical panel or cabinet.

Distribox can have a rear cable or a simple rear terminal block.
In this way, the #distribution #box can be mounted on the front of an electrical panel or cabinet.
Available with M12, M8 connectors, female sockets or male plugs.


November 16, 2012

Y Splitter, #M12-M12 #connector

Splitter useful to join on the same cable the signals coming from 2 different #sensors or to control 2 #electrovalves.
Solutions with direct cable instead of plug or socket connectors are available as well.
 
distributor M8-M8, M-M12-M12, M8-M12
Splitter allows to use 1 single cable for 2 sensors or 2 valves.
Variants: each connector could be replaced by a cable,
moreover each connector could be male or female type.



November 09, 2012

#Receptacles

M8, M12, M23, 7/8", female sockets or male plugs
Examples of receptacles for panel applications

#M8, #M12, #M23, 7/8", male plug or female socket, angled or straight for mounting on panel.
Available with unsheathed or sheathed wires, with soldering or for printed circuit contacts.


October 24, 2012

Extension cord #M12 / #USB

connecting cables, extension cords, jumping cords
Extension cord with several combination available

#Extension cords are available with the following #connectors at each side:
  • USB standard type A or type B connector
  • USB micro connector
  • M12 male / female and with / without nut connected to the cable shielding.
  • Can be used as an adaptor as well

May 17, 2012

Distribution #Backbone #Chain


Chain made of electrical connections series.
The backbone is usually made with wires of 1,50 mm² or 2,5 mm².
Infinite number of connections.
The distance between 2 connections is upon request. Typically 1 meter.
Each output can be direct cable or connector, male or female, M8 or M12.
Example of application: #Led #illumination.

Electrical connections or wiring harnesses
Each output can be cable or connector.

April 17, 2012

Distribution box with #input and #output connectors of various sizes

SK3FxPD is a distribution #box family with triple line of output #connectors. The output connectors in the same box may be of different sizes and poles quantity. The control connector is a 7/8" of 14 or 19 or 25 poles (M23 of 12 or 19 poles). Caps for dust protection are available.
Advantages:
  • reduction of boxes quantity
  • no more need of adaptors
  • possibility to prevent connection mistake using different sizes and codings.
Shield distribution box can be an alternative or complementary BUS applications.

 M8, M12, 7/8", M23 plug or socket connectors
No more adaptors! Distribution box can be supplied with input and output connectors of various types.


February 10, 2012

Top mounting Distribox series

M8, M12 distribution box, up to 15 actuator / sensor sockets
Shield – M12 – M8 Series top assembly distribution box.

Distribution boxes,
top mounting M8 and/or M12 sockets,
from 2 to 15 sockets,
1, 2 or 3 signals each #female socket,
with or without signalling Led,
for #connection of #sensors, #actuators, etc.;
special circuits on request.

December 19, 2011

Triple exit #connector

Multiple exit cable connector,
to connect up to 3 #sensor switches each socket,
when used with an appropriate
distribution #box.
Application example: sensors connection.
Distribution box with triple signal
Distribution Box with triple signal M12 connector.

December 12, 2011

Triple #Distribox

Star shape Distribox,
triple line M12 female sockets,
from 3 to 15 sockets,
for #sensors #electrovalves, etc.


for sensors and electrovalves
Star shape Distribution Box with M12 angled connectors

June 25, 2010

#Cable Maximum Voltage Rating and #Mechanical Strength

Tips to choose a cable.
The maximum voltage depends on the material characteristics, the conductor insulation thickness and the outer sheath thickness. The insulation must be sufficiently resistant to prevent even accidental crushing situations, so different uses can have different requirements of project. Norms as UL and CSA (American), IEC (International) and EN (European) set values which are not always equal to each other and sometimes refer only to heavy employment, such as cables for power transmission.
Cable max current
For the transmission of signals inside industrial machinery, it is frequent to use reduced thickness which refers to commercial standards which are not supported by norms, such as cables LiYY and FROR. The advantage of using reduced thickness is particularly evident in the smaller volume occupied by bundles of cables. The reference nominal voltage is generally at least 300 V. On the market there are also low-cost cables in PVC, with extremely reduced thickness, which may not be compatible with the safety standards for specific applications; it is advisable to carefully evaluate the characteristics of the products.
The norm IEC 60204-1 (#Machinery #Safety) recommends the minimum section of the cables according to the application as well, see table 1 on page http://www.shield.net/files/catalogue/support/2.2.pdf. The norm allows smaller sections only if the mechanical protection is sufficiently guaranteed, for example with conduits.

June 04, 2010

#EN175301-803 connectors

These connectors are also called as #DIN 43650, #ISO 4400, ISO 6952, ISO 15217 electrovalve connectors. They can be made with shielded or unshielded cables, halogen free polyurethane cables, PVC or silicone cables with dynamic or static application. Ratings up to 10A, 250V. Electronics: custom electronic circuit design available. This connector style is also available as field attachable version, with screw terminals or crimp contacts.

male and female connectors
connector + connector

VC series electrovalve EN175301-803 DIN 43650 ISO 4400 screw connectors

7/8" connectors

7/8" angled connector with cable. HDM Shield series connectors, angled shape, 7/8 inch thread. Poles quantity (from 2 to 14) and many combinations of thread and poles gender offer to the designer a wide range of different connections.#Shield manufactures #connectors for industrial #hydraulic, pneumatic, electrical #automation, illumination, trucks and various construction equipments. These photos show 7/8" circular angled and straight connector series with shielded or unshielded cable. The cable materials can be chosen among a wide choice: halogen free, polyurethane, PVC, silicone, etc. Dynamic or static application. 2, 3, 4, 5, 6, 14, 19, 25 poles.

7/8" straight connector with cable. HDL Shield series connectors, straight shape, 7/8 inch thread. With shielded or unshielded   cables. They are usually applied on small motors or distribution   boxes.7/8" frontal assembling receptacle with wires. HDE Shield series receptacles, 7/8 inch thread. Frontal assembling method. Poles quantity (from 2 to 14) and many combinations of thread and poles gender offer to the designer a wide range of connections.

Gender configurations can be: standard male, female and hybrid male-contacts / female-thread, female-contacts / male-thread. Ratings up to 13A, 600V. IP68 over-molded cables. Clean design.
Receptacle can be supplied with frontal or rear assembly method.